Skip to content

What Size Air Conditioner Do I Need? A Room-by-Room Guide

How to work out what size air conditioner you need in the UK: a simple kW rule of thumb, BTU conversions, room examples and when to get a survey.

By GreenAir Air Conditioning6 min read

Illustration of air conditioner sizing: room floor area multiplied by roughly 0.1 kW per square metre, adjusted up for sun, glass, kitchens and people, with too small and too big both marked as problems and a survey to confirm the size

If you are wondering what size air conditioner you need, the quick answer for a typical UK room is roughly 0.1 kW of cooling for every square metre of floor, then adjusted up for sunny, glazed or busy rooms. That gets you into the right ballpark. This guide shows you how to do the sum, what changes it, and why a proper survey still matters before you buy.

Air conditioning sizes: kW and BTU

Air conditioners are sized by how much heat they can move, which is called their capacity. In the UK and Europe this is usually given in kilowatts (kW). You will also see BTU (British Thermal Units per hour), especially on portable units and online listings.

The conversion is simple: 1 kW is about 3,412 BTU per hour.

Domestic wall-mounted units are commonly sold in a handful of standard sizes. Here is roughly how they line up:

Nominal size Approximate BTU/h Often sold as
2.5 kW 8,500 "9,000 BTU"
3.5 kW 11,900 "12,000 BTU"
5.0 kW 17,100 "18,000 BTU"
7.0 kW 23,900 "24,000 BTU"

Exact sizes vary between models and manufacturers, and the BTU names are rounded for marketing, so always check the capacity figures on the specification sheet.

One more thing to check: most split systems list two capacities, one for cooling and one for heating. If you plan to use your air conditioning to keep warm in winter, look at both. Our guide on whether air conditioning can heat your home explains how the heating side works.

The rule of thumb: 0.1 kW per square metre

Daikin's air conditioner size guide gives a starting rule of thumb for typical UK homes of around 0.1 kW per square metre, assuming an average ceiling height and average insulation. Other UK guides use similar figures.

To use it:

  1. Measure the room. Length × width in metres gives the floor area in square metres (m²).
  2. Multiply by 0.1. That gives a rough cooling capacity in kW.
  3. Adjust for the room (see below), then round up to the nearest standard unit size.

For example, a bedroom that is 3.5 m × 4 m is 14 m². Multiply by 0.1 and you get 1.4 kW. That is below the smallest common wall unit, so the smallest size in a range would usually be plenty, unless the room has something unusual about it.

It really is a rough guide. It tells you whether you are looking at a small, medium or large unit, not the exact model to order.

What pushes the size up (or down)

Two rooms with the same floor area can need quite different units. These are the things that make the biggest difference.

Sun and glass

Rooms with large south- or west-facing windows, roof lights or glass doors pick up a lot of heat from the sun on summer afternoons. Conservatories and orangeries are the extreme case, where the rule of thumb can badly underestimate what you need. If a room has a lot of glass, assume you need more than the basic sum suggests and get it assessed properly.

Ceiling height and the roof

The 0.1 kW figure assumes a normal ceiling height. A room with a high or vaulted ceiling has more air to cool. Loft rooms and top-floor rooms also sit right under the roof, which can get very hot in summer, so they often need more capacity than a downstairs room of the same size.

Insulation and the age of the building

A well-insulated modern room holds its temperature better than one with thin walls or single glazing. Older houses with solid walls, or extensions built to different standards from the rest of the house, can behave very differently from room to room.

People and equipment

Every person in a room gives off heat, and so do computers, TVs, ovens and hair dryers. A home office with two screens, a busy kitchen-diner or a lounge where the family gathers all need more capacity than a spare bedroom of the same size.

How you will use it

A bedroom used mainly at night faces less sun than a lounge used on a hot afternoon. If you want the unit to heat the room through winter as well, the heating capacity needs to suit the room too.

A room-by-room guide

These are rough starting points, not a sizing service. They show which way each type of room tends to lean compared with the basic sum.

  • Bedrooms: usually sit close to the basic sum, especially if the room is shaded or north-facing. Quiet operation matters more here than extra power.
  • Living rooms: often at or slightly above the basic sum, because they are used in the afternoon and evening, with more people and electronics.
  • Kitchen-diners and open-plan spaces: usually above the basic sum because of cooking heat, appliances and large glass doors. Open-plan layouts can also make it harder for one unit to reach every corner.
  • Home offices: small rooms, but computers and screens add heat all day. Lean slightly above the basic sum.
  • Loft conversions and top-floor rooms: often above the basic sum because of heat coming through the roof.
  • Conservatories and garden rooms: frequently well above the basic sum because of the glass. These always need a proper assessment.

If you want to cool several rooms, you can either fit a separate system in each or use a multi-split system, where one outdoor unit serves several indoor units. Each indoor unit is still sized for its own room.

Why the right size matters

It is tempting to buy the biggest unit you can, just to be safe. That is not always a good idea.

Too small

An undersized unit runs flat out on hot days and still cannot get the room down to the temperature you want. It works hard, uses electricity and leaves you uncomfortable.

Too big

An oversized unit cools the room quickly, then switches off, then on again. This is called short cycling. Air conditioning also removes moisture from the air, and that needs the unit to run steadily for a while. A unit that keeps stopping and starting can leave a room cool but clammy. It also costs more to buy than you needed to spend.

Modern inverter units help here. Their compressor can slow down once the room is close to the set temperature instead of just switching off, so they handle a slightly generous size much better than older on-off units. Even so, a unit that is far too big for the room will not run at its best.

Once your system is installed, the setting you choose matters too. See what temperature to set your air conditioning to for sensible summer and winter settings.

Why a survey beats a calculator

Online calculators and rules of thumb are useful for a first idea, but they cannot see your room. A proper survey looks at:

  • the room's size, shape and ceiling height
  • which way the windows face and how much glass there is
  • insulation, wall construction and what is above and below the room
  • how many people use it, when, and what equipment is in there
  • whether you want heating as well as cooling
  • where the indoor and outdoor units can go, and the pipe route between them

That last point often decides which system makes sense as much as the capacity does. A good installer will explain why they have recommended a particular size, rather than just quoting for the biggest unit.

For an idea of what affects the overall cost of a system, see our air conditioning cost guide.

Get the size right first time

The rough sum is easy: floor area × 0.1 gives you a starting figure in kW, and sunny, glazed, busy or top-floor rooms need more. For anything beyond a simple, shaded bedroom, it is worth having the room assessed before you buy.

GreenAir sizes, supplies and fits air conditioning for homes and businesses across Birmingham and the West Midlands. Find out more about our air conditioning installation service, or contact us for a free quote and we will recommend the right size for your rooms.

More Air Conditioning Advice